0% Complete
صفحه اصلی
/
سی و سومین کنفرانس بین المللی مهندسی برق
Evaluation of Blood Bilirubin via Visible Light Waves
نویسندگان :
Reyhane Zarei
1
Mousa Shamsi
2
Amin Eidi
3
1- دانشگاه صنعتی سهند
2- دانشگاه صنعتی سهند
3- دانشگاه تبریز
کلمات کلیدی :
optical biosensor،bilirubin،human blood،visible light wave
چکیده :
Abstract—A high level of bilirubin concentration in newborn blood is one the most important screening programs in the early days after birth. This can lead to jaundice if it doesn’t diagnosed at the beginning stages. Spectrophotometric devices are one of the most basic methods for analyzing bilirubin concentration. On the other hand, this method is roughly complex and time-consuming. Biosensors are usable for quick detection. Optical biosensors are used for the detection of blood parameters and biological liquids. In this work, the bilirubin of blood is evaluated. Optic waves detect pathogenic factors like bilirubin. At first, the effective wavelength for bilirubin detection was determined at 470 nm. Also, the fabrication possibility of the proposed bilirubin sensor is investigated. Then, the refractive index of blood for bilirubin concentration in 0.1, 1.85, 3.6, 5.35, and 7.1 is obtained. The proposed system can detect bilirubin up to a concentration of 7 mg/dL. Finally, the proposed design and its results are simulated by COMSOL multiphysics software to evaluate the proposed sensor performance. In this way, users can measure bilirubin without any complex spectrophotometric equipment. Furthermore, this sensor can be inserted into other medical devices to enhance accuracy.
لیست مقالات
لیست مقالات بایگانی شده
Incentivizing Peer-to-Peer Energy Trading in Microgrids
Amir Noori - Babak Tavassoli - Alireza Fereidunian
Establishment of a Virtual Power Plant in Grid for Maximizing Producers' Profits and Minimizing Pollutant Emissions and Investment Costs
Amir Hossein Gholami - Amir Abulfazl Suratgar - Mohammad Bagher Menhaj - Mohammad Reza Hesamzadeh
تجزیه و تحلیل امواج فیبریلاتور دهلیزی به منظور طبقهبندی AF با استفاده از موجک لیدر
سارا میهن دوست
A Single-Switch High Voltage Gain DC-DC Converter Using Coupled Inductor and Switched Capacitor-Inductor Techniques
Mohammad Salehizadeh - Hasan Rastegar - Farid Mohammadi
Cooperative Coverage Path Planning Using Q-Learning and Sarsa in Two Environments
Alireza Nezamzadeh - Hamed Jalaly Bidgoly - Marzieh Kamali
یک روش موازی برای تخمین حالت سریع در سیستم های قدرت با ابعاد بزرگ با استفاده از تکنیک جداسازی گراف
بهنام کریم سرمدی - احمد صالحی دوبخشری
MoMed: An Affordable Mechanical Ventilator
Mahdi Robati - Ali Sadighi - Mohammad Ali Nazari - Hamid Naseri
حسگر غیرتهاجمی تشخیص قندخون با استفاده از تکنیک مایکروویو بر مبنای تشدید فرکانسی
نازنین افشاری - سید محمد هاشمی - فاطمه گران قراخیلی
Switched Robust Model Predictive Based Controller for UAV Swarm System
Erfan Nejabat - Amirhossein Nikoofard
True Random Number Generator Relying on Multiple Entropy Source and Triple Oscillator for Cryptography Purposes
Somayeh Gholam Mehraban - Mohsen Jalali - Mostafa Azadbakht
بیشتر
ثمین همایش، سامانه مدیریت کنفرانس ها و جشنواره ها - نگارش 43.6.0