0% Complete
صفحه اصلی
/
سی و سومین کنفرانس بین المللی مهندسی برق
Designing a delay line independent of PVT (Process, Voltage, Temperature) and applying it to a TDC (Time to Digital Converter)
نویسندگان :
Sepehr Zare Teimoori
1
Mehdi Ehsanian
2
1- دانشگاه صنعتی خواجه نصیرالدین طوسی
2- دانشگاه صنعتی خواجه نصیرالدین طوسی
کلمات کلیدی :
Time to Digital Converter (TDC)،PVT Detector،Delay Line
چکیده :
In this research, a CMOS delay line in 0.18 μm technology with very low sensitivity to environmental effects (PVT) and high linearity is introduced and used as the input of an 8-bit Time-to-Digital Converter (TDC) with a Flash structure. The received delay resolution of this delay line is about 81 picoseconds and the resulting dynamic range is about 735 picoseconds. The measured delay changes without correction for the error introduced by PVT variations are about 73 picoseconds (approximately equal to the delay resolution), which is reduced to about 24 picoseconds after the PVT Detector circuit automatically detects and corrects the destructive PVT conditions. Also, the power consumption obtained from this design is 1.24 milliwatts.
لیست مقالات
لیست مقالات بایگانی شده
Investigation of Impact Ionization Variations Versus Electric Field and Temperature in Compound Semiconductors for UV-APD Applications
Mohammad hossein Khoddami - Hassan Kaatuzian - Mohammad hossein Asgari
A New Atrial Fibrillation Detection System with Noise Cancellation and Signal Annotation
Amirali Banaei Kashani - Bardia Baraeinejad - Mohammad Fakharzadeh
ساخت حسگر مقاومتی بخار اتانول مبتنی بر هتروساختار باریم تیتانات / اکسید روی آلاییده با نانوذرات نقره
محسن طاهری پور - نوید یثربی - شیرین نصراصفهانی - محمد حسین شیخی
Non-pharmacological interventions for Covid-19 new variants with fractional order fuzzy type-2 PID
Hadi Delavari - Amir Veisi - Maryam Ranjbaran
HIV Virus States Estimation by Extended Kalman Particle Filter
Meysam Hooshmand - Mahtab Sharifian - Hamid Sharifian - Javad Mahmoudi
Improving the Performance and Robustness of Non-Minimum Phase Systems Using Integrated Feedforward-IMC Technique
Saeedreza Tofighi
An Accurate Subthreshold Analytical Model for Black Phosphorus Heterojunction Dopingless Tunneling Field-Effect Transistors
Saeid Marjani - Mohamad Tolue Khayami
Service Restoration in Distribution Networks Based on a Two-stage Power Flow Model
Saman Armand - Jalal Heidary - Eli Shirazi
طراحی کنترلکنندهی جدولبندی بهرهی پسخورد خروجی کلیدزن مقاوم برای سیستمهای پارامتر متغیر خطی نامعین چندوجهی پیوسته-زمان
رضا یاوری - سعید شمقدری - آرش صادقزاده
Comparison of Channel Selection Methods for EEG Signal Classification
Soraya Charkas - MohammadBagher Shamsollahi
بیشتر
ثمین همایش، سامانه مدیریت کنفرانس ها و جشنواره ها - نگارش 43.6.0