0% Complete
صفحه اصلی
/
سی و یکمین کنفرانس بین المللی مهندسی برق
A novel protection scheme for HVDC transmission lines based on DC-filter current and DC line current
نویسندگان :
Mohammad Amin Rezaei Gazik
1
Hossein Kazemi Karegar
2
1- دانشگاه شهید بهشتی تهران
2- دانشگاه شهید بهشتی تهران
کلمات کلیدی :
HVDC،filter،protection،current،fault
چکیده :
Abstract— HVDC effectively transmits large amounts of electrical energy using DC (direct current) over long distances by overhead transmission lines, underground cables, and submarine cables. HVDC system is also used to connect separate power systems with different characteristics and frequencies in which AC transmission is impossible [1]. HVDC transmission line protection is essential for the safety and reliability of the power grid due to the extensive use of the HVDC transmission line. Various faults can occur in the HVDC system, such as AC, internal converter, and DC faults. Failure may occur due to insulation failure due to short circuits, switching, and lightning, which imposes new challenges to protecting the HVDC transmission line. To address these challenges, a new protection scheme for HVDC transmission lines is proposed in this paper based on the flow characteristics of DC filters and DC line current. The flow characteristics of DC filters and the current passing through the DC line are theoretically analyzed for internal and external faults in a constant fault period. Moreover, this flow profile is used as a backup protection scheme to identify pole-to-ground faults, the worst of all. A 500 kV HVDC system built in PSCAD/EMTDC is used to verify the validity of the proposed protection scheme. The simulations show that the protection scheme proposed in this paper can not only accurately detect internal and external faults but is not sensitive to the amount of fault resistance and distance.
لیست مقالات
لیست مقالات بایگانی شده
Structural Stability and Electron Density Analysis of Doped Antimonene: A First-Principles Study
Arash Yazdanpanah Goharrizi - Peyman Saberi Parsa
Distributed Deep Reinforcement Learning for Radio Resource Management in O-RAN
Ahmad Ahmadi Siahpoush - Vahid Shah-Mansouri
Depth Estimation in Monocular Images of Inside the Sewer Pipes for Navigation of Inspection Robots
Zeinab Maroufi - Alireza Hadi Hosseinabadi - Reza Askari moghadam
Anomaly Detection in Urban Water Distribution Grids Using Fog Computing Architecture
Sara Mirzaie - Mohammadreza Avazaghaei - Omid Bushehrian
Stable Target Tracking in Wireless Sensor Networks Under Malicious Cyber Attacks
Jafar Akhondali - Mohammad Taheri
طراحی و ساخت سیستم تصویربرداری SAR دایروی موج میلیمتری
علی آقاکثیری - امیرعلی بنایی کاشانی - علی تاجیک - علیرضا کیایی - هنگامه عزیزی - مهدی عندلیبی - سامان غضنفری - محمد فخارزاده
طراحی خودرمزگذار متغیر جهت تشخیص عیب در بیرینگهای غلتشی
مریم آهنگ - مهدی علیاری شورهدلی
امکان استفاده از پلی آنیلین دوبعدیC3N به عنوان آشکار سازِ گاز استالدهیدِ بازدم در دستگاه های تشخیصِ غیر تهاجمیِ سرطان ریه: مطالعه اصل اولیه
محمد حسین امیدواری - حامد مهدوی نژاد - رزا صفایی اسدآبادی - محمدحسین شیخی
گیت Xor/Xnor جدید با مصرف توان پایین مبتنی بر تکنولوژی اسپینترونیک
ایمان علیبیگی - محمود تابنده - سعید باقری شورکی - رامین رجایی
A New Atrial Fibrillation Detection System with Noise Cancellation and Signal Annotation
Amirali Banaei Kashani - Bardia Baraeinejad - Mohammad Fakharzadeh
بیشتر
ثمین همایش، سامانه مدیریت کنفرانس ها و جشنواره ها - نگارش 43.6.0