0% Complete
صفحه اصلی
/
سی امین کنفرانس بین المللی مهندسی برق
Design and Performance Analysis of a Novel Optical Biosensor for Measuring Glucose Concentration in Urine
نویسندگان :
Sania Eskandari
1
Siavash Zargari
2
Saeed Meshgini
3
Ali Farzamnia
4
1- دانشگاه تبریز
2- دانشگاه تبریز
3- دانشگاه تبریز
4- Universiti Malaysia Sabah
کلمات کلیدی :
Glucose concentration،Biosensor،Photonic crystal،Ring resonator
چکیده :
This paper presents a diamond-shaped biosensor using a two-dimensional photonic crystal to measure the glucose concentration in urine. The proposed sensor is designed to operate linearly in the range of 0 - 5 gm/dl. The size of the designed biosensor is 11.4 m × 11.4 m and consists of a ring resonator and two waveguides. The ring resonator is mounted in the center of the structure with two end waveguides on both sides. The detection process is based on the resonant wavelength shift due to the change in the analyte refractive index. The proposed sensor is analyzed by COMSOL Multiphysics software, and MATLAB is used to plot the simulation results. The results demonstrate that the resonant wavelength shift is linearly related to the changes in the refractive index. The maximum quality factor and the sensitivity of the biosensor are respectively obtained around 1874.83 and 364.54 nm/RIU. Such an attribute combination turns the designed structure into a promising element for medical and biological applications.
لیست مقالات
لیست مقالات بایگانی شده
An Investigation of Hardware Implementation of Multi-Valued Logic Using Different Nanodevices
Abdolah Amirany - Kian Jafari - Mohammad Hossein Moaiyeri
A Bidirectional Transformerless Direct AC-AC Dynamic Voltage Restorer with Extended Compensation Range and Up/Down Capability
ُSeyed Mohsen Mortazavi - MohammadHadi Mokhtari - Mohammad Reza Zolghadri
Defects Dynamics in Multilayer h-BN Resistive Switching Memories: A Molecular Dynamics Investigation
Omid Babaeinejad - Maryam Keshavarz Afshar - Ebrahim Nadimi
Hand Movment Decoding from EEG Signals Using Kalman Filter with Parameters Estimated via Neural Networks and Least Squares Method
Pegah Khoshkavandi - Mohammad B Shamsollahi - Ali Motie Nasrabadi
Enhancing Kriging with Inductive Spatio-Temporal GraphODE
Amin Sheykhzadeh - Behzad Moshiri - Ebrahim Ghafar-Zadeh
Scaled CR-(RC)n Digital Filter Design for Precision Pulse Processing in Spectroscopy Applications
MohammadReza Fazli - Nasser Masoumi - Hamid Rahimpour
Study of Performance Characteristics of a Line-Start Synchronous Reluctance Motor Over its Synchronization Region
Ali Jamali-Fard - Mojtaba Mirsalim
Power Consumption and I/Q-to-Phase Analysis in Direct Demodulation Approaches
Mir mahdi Safari - Jafar Pourrostam
Reliability-Based Design of Time-Varying Electricity Tariff
Mohammad Rastegar - Nima Sarajpoor
High PSRR, 0.7nW MOSFET-Only Subthreshold Voltage Reference
Mohammad Rashtian - Mahdi Shahpasandi
بیشتر
ثمین همایش، سامانه مدیریت کنفرانس ها و جشنواره ها - نگارش 43.6.0