Inexpensive fabrication of stretchable dry EEG electrodes using well known dry film photoresists
نویسندگان :
Mohammad Sadegh Rasekh
1
Amir Jahanshahi
2
Hassan Ghafoorifard
3
1- دانشگاه صنعتی امیرکبیر(پلی تکنیک تهران)
2- دانشگاه صنعتی امیرکبیر(پلی تکنیک تهران)
3- دانشگاه صنعتی امیرکبیر(پلی تکنیک تهران)
کلمات کلیدی :
flexible electronics،stretchable electronics،dry electrodes،EEG،dry film photoresist
چکیده :
with the discovery of new brain diseases, clinical tests for Electroencephalogram (EEG) have become more important every day. Commercially available wet Ag/AgCl electrodes apply conductive gel to the scalp of the subject before recording the EEG signal. After applying the gel, the impedance is gradually decreased and the EEG signal can be received. In the long run, the conductive gel dries and the impedance increases again. The gel also causes skin irritations in the course of time as well. Therefore, Ag/AgCl .electrodes are inappropriate to be used in the long term measurements Dry electrodes are introduced as a gel free no preparation alternatives of wet electrodes in the literature. In this manuscript, a novel flexible and stretchable dry EEG electrode is demonstrated. The electrode features four conductive pads to contact the scalp. The stretchable electrodes are embedded in elastomer. A flexible polyimide layer supports the conductive electrodes to increase mechanical reliability in elongations. The electrodes are produced using a relatively straightforward and cost-effective fabrication method namely commercial dry film photolithography. The latter is well known for the high-volume fabrication of printed circuit boards (PCB). The EEG signal is recorded with the fabricated electrode as well as wet Ag/AgCl electrodes. The received signals from the two electrodes feature relatively high correlation.
لیست مقالات
لیست مقالات بایگانی شده
A Coronavirus Herd Immunity Optimizer For Intrusion Detection System
Amir Soltany Mahboob - Hadi Shahriar Shahhoseini - Mohammad Reza Ostadi Moghaddam - Shima Yousefi
Open Circuit Fault Detection and Diagnosis for Seven-Level Hybrid Active Neutral Point Clamped (ANPC) Multilevel Inverter
Mobin Azimipanah - Mahyar Hassanifar - Yousef Neyshabouri
Study of Plasmonic Perfect Absorber Using Three Dimensional Silver Double Triangle-Shaped Nanoparticles
Mohammad Reza Rakhshani
برنامه ریزی مسیر حرکت ربات در بین عابران پیاده با پیشبینی حرکت عابران
ملیکا رضوانی - سمانه حسینی
Development of a Tilt Bicopter: Experimental Results
Ali Moaveni - Alireza Bahmanyar - Arshia Rezaei - Amin Talaeizadeh - Aria Alasti
An Improved Version of the SIPO Algorithm with Fast Convergence Speed
Amir Soltany Mahboob - Hadi Shahriar Shahhoseini - Mohammad Reza Ostadi Moghaddam - Shima Yousefi
شبیه سازی رفتار و عملکرد مقره پلیمری 20 کیلوولت با اعمال آلودگی سطحی از نقطه نظر ارزیابی و سنجش جریان خزشی و ارائه الگوی معادل سازی آن
سیدمحمدعلی طباطبائی - حمید جوادی - مسعود عبدالحسین پور - فرامرز قلیچی
Stability Analysis of Singular 2-D Positive systems
Mahmoud Zamani - Masoud Shafiee - Iman Zamani
ارائه یک مبدل DC-DC منبع امپدانسی تک سوئیچه تک هسته مغناطیسی فوق افزاینده مناسب برای استفاده در کاربرد های انرژی نو
معصومه پرستش - سجاد رستمی
Design and Performance Analysis of a Novel Optical Biosensor for Measuring Glucose Concentration in Urine
Sania Eskandari - Siavash Zargari - Saeed Meshgini - Ali Farzamnia
ثمین همایش، سامانه مدیریت کنفرانس ها و جشنواره ها - نگارش 40.4.2