0% Complete
صفحه اصلی
/
سی و سومین کنفرانس بین المللی مهندسی برق
Energy Efficiency Evaluation of a Line-Start Permanent Magnet Assisted Synchronous Reluctance Motor for Pump Application
نویسندگان :
Ali Jamali-Fard
1
Mojtaba Mirsalim
2
1- Amirkabir University of Technology (Tehran Polytechnic)
2- Amirkabir University of Technology (Tehran Polytechnic)
کلمات کلیدی :
Synchronous reluctance motor (SynRM)،line-start،permanent magnet (PM)،pump application،finite element analysis (FEA)
چکیده :
Due to their numerous advantages, induction motors (IMs) have garnered significant interest over the years. Addressing the critical issue of reducing energy consumption, optimizing electric motors remains a paramount concern. However, the presence of Ohmic losses in the rotor cage of IMs limits their efficiency. In recent years, several studies have explored replacing IMs in fan and pump applications with alternative electric motor types to enhance efficiency. One promising option is the line-start permanent magnet-assisted synchronous reluctance motor (LS-PMaSynRM), which can achieve IE4 and potentially the upcoming IE5 efficiency classes for the same output power compared to IMs. This work extends the authors' previous efforts in implementing LS-PMaSynRMs for fan and pump applications. The paper focuses on rotor design using three-dimensional finite element analysis (FEA) and the standard prototyping process of an LS-PMaSynRM for pump applications. A benchmark 0.75kW-1500rpm IM is considered, with its rotor replaced by the newly designed rotor. The finite element analysis results are presented and discussed. Simulation results are further validated through experimental prototyping and testing of the case-study motor. Finally, the performance characteristics of the prototyped motor are compared with those of a counterpart IM.
لیست مقالات
لیست مقالات بایگانی شده
Safe Cooperative Control of Non-Holonomic Mobile Manipulators
Zahra Kashi - Nargess Sadeghzadeh-Nokhodberiz
Achieving a Wide Range of Voltage Gain in Three-Phase LLC Resonant Converter Using Hybrid Control of Variable Frequency and Variable Magnetizing Inductor
Saeed Ramezani darvish - Salar Sadeghian - Adib Abrishamifar
Exploring the Impact of Machine Translation on Fake News Detection: A Case Study on Persian Tweets about COVID-19
Masood Hamed Saghayan - Seyedeh Fatemeh Ebrahimi - Mohammad Bahrani
(Room Temperature Chemiresistor H2S Gas Sensor based on ZnS/PbS Core-Shell Quantum Dots(CSQDs
Mojtaba Azimi - Ali Rostami
Perfect Tracking of a Non-minimum Phase MIMO System
Saeedreza Tofighi - Farshad Merrikh-Bayat
تجزیه و تحلیل امواج فیبریلاتور دهلیزی به منظور طبقهبندی AF با استفاده از موجک لیدر
سارا میهن دوست
Non-isolated Ultra-high Step-Up Quadratic Converter With Low Voltage Stress and Continuous Input Current
Maryam Hajilou - Baharak Akhlaghi - Hosein Farzanehfard
Robust Wireless Power Transfer by Self-Oscillating Controlled Inverter and Double-D Pads
Alireza Eikani - Mohammad Amirkhani - Hossein Jafari - Hesamodin Abdoli - Sadegh Vaez-Zadeh - Ghasem Rezazadeh
Flexible Generation Expansion Planning Considering Representative Days of Load and Renewable Variations
Peyman Amirian - Zeinab Maleki - Mohammad-Amin Pourmoosavi - Turaj Amraee
Noninvasive Diagnosis of the Type of Breast Tumor through Artificial Neural Networks
Pooya Tahmasebi - Maryam Mehdizadeh Dastjerdi - Ali Fallah - Saeid Rashidi
بیشتر
ثمین همایش، سامانه مدیریت کنفرانس ها و جشنواره ها - نگارش 43.6.0