Effective Service Restoration in Electrical Distribution Networks Using a Bi-Stage Algorithm
نویسندگان :
Qasem Asadi
1
Amir Amini
2
Hamid Falaghi
3
Maryam Ramezani
4
1- شرکت برق منطقه ای خراسان
2- شرکت برق منطقه ای خراسان
3- دانشگاه بیرجند
4- دانشگاه بیرجند
کلمات کلیدی :
Electrical Distribution System (EDS), Service Restoration, Remote Controlled Switch, Bi-Stage Algorithm, Energy Not Supplied
چکیده :
In Electrical Distribution System (EDS), usually following an outage, significant time is spent on fault locating, isolating the fault zone, and energizing upstream and downstream loads. In addition to dissatisfaction in residential customers, electricity interruption even for a few seconds, can cause huge damages in advanced industries or critical customers. Currently EDSs are equipped with Manually Switches (MS) and Remote Controlled Switches (RCS). The heuristic Service Restoration (SR) algorithm of this paper is a Bi-Stage algorithm that at the first stage quickly restore energy to some loads using RCSs and in the second stage, all types of switches (MSs and RCSs) are used to complete the SR process. Here, to solve the SR problem, minimizing Energy Not Supplied (ENS) is selected as the objective function. The proposed SR algorithm was performed on a sample network in different situations. In addition to using a Bi-Stage SR algorithm to minimize ENS and re-energizing customers in the shortest time after fault, taking into account the actual network conditions such as load profiles, network operation constraints and providing switching sequence also increase the attractiveness of the proposed algorithm. Finally, it was proved that using proposed SR algorithm it is possible to achieve optimal and efficient solutions matching today's EDSs.
لیست مقالات
لیست مقالات بایگانی شده
High-Resolution Remote Sensing Image Captioning Based on Structured Attention and SAM Network
Yassin Riyazi - Seyyed Mostafa Sadjadi - Abbas Zohrevand - Reshad Hosseini
A New Method on Failure Detection of Fixed and Moving Contacts of Circuit Breakers
Hassan Hamidi - Ali Asghar Razi Kazemi
Millimeter-Wave Imaging System: A Brief Study on System Performance
Behnam Ghandi - Sobhan Dabidian - Sina Zeraatkar - Zahra Kavehvash
Gearbox Fault Detection Using Continuous Wavelet Transform and Vision Transformer (ViT)
Ali Asadian - Yassin Riyazi - Moosa Ayati
Vibration Analysis of a High-Speed Switched Reluctance Motor Considering Fast Demagnetization Voltage
Nasrin Majlesi - Amir Rashidi - Morteza Saghaian Nejad
Evaluation of Different Connectivity Methods for Obsessive Compulsive Disorder Diagnosis
Samandokht Rashidi - Amin Abdipourasl - Fatemeh Jamaloo - Reza Rostami
A Novel Interpretation of Coding in Time-Modulated Arrays
Mehdi Gholami - Mohammad Neshat
Holographic Technique Inspired Multi-Beam Cylindrical Leaky-Wave Antenna
Mohammad Amin Chaychi Zadeh - Nader Komjani - Sajjad Zohrevand
بازشناسی مقاوم زمانی – مکانی انسان در یک سیستم نظارتی بر اساس شبکه GAN
آزاده سادات موسوی - شهریار برادران شکوهی
Parkinson’s Disease Classification Using Continuous Wavelet Transform and Ensemble Convolutional Neural Networks on EEG Signals
Seyed Pedram Monazami - Raheleh Davoodi
ثمین همایش، سامانه مدیریت کنفرانس ها و جشنواره ها - نگارش 40.4.2